Technology

An objective measure of diaphragm function

Non-Invasive

  • DXT sensors with optimized design for patient comfort

Continuous monitoring

  • > 24 hours real-time monitoring

Easy to use

  • Actionable output to diagnose diaphragm dysfunction
  • DXT tape with integrated ultrasound gel
  • Computer aided sensor placement
  • No ultrasound expertise required

With DXT, we aim to optimize extubation timing, reduce re-intubation rate, improve patient outcomes, and thereby reduce healthcare costs.

“We recommend that the estimation of diaphragmatic excursion for diaphragmatic function assessment, mainly in patients to be weaned from mechanical ventilation, should be considered a basic skill for intensivists.“ Consensus and expert recommendations of the European Society of Intensive Care Medicine, 2021

 

Respinor animated sensor with monitor

Medical need

Mechanical ventilation (MV) is one of the most common therapies in the intensive care unit (ICU), and it is a treatment that patients only receive in the most life-critical situations. Every extra day a patient is on MV, the risk of permanent impairment to the breathing ability increases along with treatment costs. Therefore, it is highly important to bring patients off MV and back to spontaneous breathing as quickly as possible. There is currently a lack of accurate and cost-effective solutions to support this process – and the introduction of new technologies is highly warranted. Respiratory problems and respiratory failure after extubation can often be directly linked with diaphragm dysfunction. However, monitoring of the diaphragm is not routinely performed, meaning that diaphragm dysfunction is often under-recognized. The introduction of RESPINOR DXT can represent a paradigm shift.

Patients are put on MV because they are unable to sustain breathing on their own in such a way as to maintain sufficient gas exchange. Patient on invasive MV in the intensive care unit. MV is a critical, life-sustaining treatment; however, it is also associated with several risks including diaphragm muscle atrophy (shrinkage due to underuse), and muscle fiber damage caused by unloading of the diaphragm as the ventilator assumes control of respiration. Diaphragm impairment has been documented to affect patients as soon as after 1 day of commencing MV. The diaphragm contributes to 70-75% of the Tidal Volume (VT), and consequently, to avoid extensive damage to the main breathing muscle, the intensive care clinician must balance the need for MV to maintain adequate gas exchange with getting patients off the ventilator as early as possible.

The process of withdrawing ventilatory support for patients is known as weaning and is based on daily observations of clinical parameters to determine whether the underlying cause of respiratory failure has been resolved. When the intensive care clinician has evaluated that the acute phase of the disease has been resolved, a spontaneous breathing trial (SBT) is conducted. The SBT assesses the patient’s ability to breathe while receiving minimal or no ventilator support and typically lasts for 30 minutes. During the SBT, the clinician evaluates various clinical parameters to help predict if the patient can be extubated successfully. For example, the rapid shallow breathing index (RSBI) is the most widely used clinical criterium to predict successful weaning and is the ratio of respiratory rate (RR) to VT. Patients on MV who are not ready to tolerate spontaneous breathing tend to breathe rapidly and shallowly and will, therefore, have a high RSBI. However, the literature presents varying degrees of sensitivity and specificity, questioning the predictive value of the RSBI.

Evaluating parameters such as RR, VT, and blood saturation allow the intensive care clinician to assess the stability of the cardiovascular and metabolic systems, as well as adequate oxygenation and pulmonary function. However, there is no consensus on the criteria for these parameters during the SBT, and the rate of reintubation has been as high as 30% in some studies. The high proportion may be due to undiagnosed diaphragm dysfunction, as the standard of care in weaning does not include direct monitoring of the diaphragm, and monitoring of VT does not uncover diaphragm dysfunction alone. The accessory respiratory muscles can increase their contribution to compensate for any deficiency of the diaphragm during the vast period of the SBT. However, as they do not have the same endurance as the diaphragm, delayed weaning failure and reintubation may occur in patients who have unidentified diaphragm dysfunction but pass an SBT. The risks associated with reintubation are severe, and include increased cardiac and respiratory complications, prolonged length of ICU and hospital stay, prolonged MV support, increased mortality, and higher costs. Direct monitoring of the diaphragm during the weaning process has the potential to optimize extubation timing and thus reduce reintubation rate, improving patient care and outcome, and reducing overall healthcare costs. However, the methods available are invasive and/or require specialist, trained operators. This may change with the introduction of RESPINOR DXT.

Progress

Technical

80%
  • Technical development of RESPINOR DXT prototype completed.
  • Design frozen for the first commercial version of RESPINOR DXT.
  • Improvement for manufacturability in process.

Clinical

80%
  • Completed clinical feasibility studies in Europe with technical proof of principle and proof of concept confirmed
  • Clinical Evidence DE-RISK WF Study ongoing in France and Norway with expected enrollment of approx. 300 patients.

CE mark

70%
  • RESPINOR has a certified QA system according to ISO 13485:2016.
  • MDR application process initiated with the notified body Tüv Süd.

"I was impressed by your device and your signal. I believe there is a lot to do with your system, to monitor the diaphragm in ICU patients, but also way beyond this application."

ICU Spesialist France